Analysis of infant cortical synchrony is constrained by the number of recording electrodes and the recording montage

Show simple item record

dc.contributor.author Tokariev, Anton
dc.contributor.author Vanhatalo, Sampsa
dc.contributor.author Palva, J. Matias
dc.date.accessioned 2017-09-14T09:51:01Z
dc.date.available 2021-12-17T18:47:03Z
dc.date.issued 2016-01
dc.identifier.citation Tokariev , A , Vanhatalo , S & Palva , J M 2016 , ' Analysis of infant cortical synchrony is constrained by the number of recording electrodes and the recording montage ' , Clinical Neurophysiology , vol. 127 , no. 1 , pp. 310-323 . https://doi.org/10.1016/j.clinph.2015.04.291
dc.identifier.other PURE: 59635599
dc.identifier.other PURE UUID: e78aa876-7fd5-4ebb-ad68-0091ce37b7ca
dc.identifier.other WOS: 000367540800043
dc.identifier.other Scopus: 84932121669
dc.identifier.other ORCID: /0000-0002-1202-9981/work/66035749
dc.identifier.uri http://hdl.handle.net/10138/223862
dc.description.abstract Objective: To assess how the recording montage in the neonatal EEG influences the detection of cortical source signals and their phase interactions. Methods: Scalp EEG was simulated by forward modeling 20-200 simultaneously active sources covering the cortical surface of a realistic neonatal head model. We assessed systematically how the number of scalp electrodes (11-85), analysis montage, or the size of cortical sources affect the detection of cortical phase synchrony. Statistical metrics were developed for quantifying the resolution and reliability of the montages. Results: The findings converge to show that an increase in the number of recording electrodes leads to a systematic improvement in the detection of true cortical phase synchrony. While there is always a ceiling effect with respect to discernible cortical details, we show that the average and Laplacian montages exhibit superior specificity and sensitivity as compared to other conventional montages. Conclusions: Reliability in assessing true neonatal cortical synchrony is directly related to the choice of EEG recording and analysis configurations. Because of the high conductivity of the neonatal skull, the conventional neonatal EEG recordings are spatially far too sparse for pertinent studies, and this loss of information cannot be recovered by re-montaging during analysis. Significance: Future neonatal EEG studies will need prospective planning of recording configuration to allow analysis of spatial details required by each study question. Our findings also advice about the level of details in brain synchrony that can be studied with existing datasets or by using conventional EEG recordings. (C) 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved. en
dc.format.extent 14
dc.language.iso eng
dc.relation.ispartof Clinical Neurophysiology
dc.rights.uri info:eu-repo/semantics/openAccess
dc.subject Neonatal EEG
dc.subject Forward model
dc.subject Simulation
dc.subject Dense array EEG
dc.subject Connectivity
dc.subject Brain development
dc.subject PRINCIPAL-COMPONENTS-ANALYSIS
dc.subject AUDITORY EVOKED-POTENTIALS
dc.subject ERP GENERATOR PATTERNS
dc.subject LAPLACIAN WAVE-FORMS
dc.subject SOURCE LOCALIZATION
dc.subject BRAIN NETWORKS
dc.subject NEONATAL EEG
dc.subject ADULT ELECTROENCEPHALOGRAM
dc.subject FUNCTIONAL CONNECTIVITY
dc.subject SPATIAL-RESOLUTION
dc.subject 3124 Neurology and psychiatry
dc.title Analysis of infant cortical synchrony is constrained by the number of recording electrodes and the recording montage en
dc.type Article
dc.contributor.organization Clinicum
dc.contributor.organization Department of Diagnostics and Therapeutics
dc.contributor.organization Neuroscience Center
dc.contributor.organization Children's Hospital
dc.contributor.organization Kliinisen neurofysiologian yksikkö
dc.contributor.organization Matias Palva / Principal Investigator
dc.description.reviewstatus Peer reviewed
dc.relation.doi https://doi.org/10.1016/j.clinph.2015.04.291
dc.relation.issn 1388-2457
dc.rights.accesslevel openAccess
dc.type.version publishedVersion

Files in this item

Total number of downloads: Loading...

Files Size Format View
Analysis_of_infant_cortical_synchrony.pdf 2.348Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record