Lazaridis , M , Eleftheriadis , K , Zdimal , V , Schwarz , J , Wagner , Z , Ondracek , J , Drossinos , Y , Glytsos , T , Vratolis , S , Torseth , K , Moravec , P , Hussein , T & Smolik , J 2017 , ' Number Concentrations and Modal Structure of Indoor/Outdoor Fine Particles in Four European Cities ' , Aerosol and Air Quality Research , vol. 17 , no. 1 , pp. 131-146 . https://doi.org/10.4209/aaqr.2015.04.0267
Title: | Number Concentrations and Modal Structure of Indoor/Outdoor Fine Particles in Four European Cities |
Author: | Lazaridis, Mihalis; Eleftheriadis, Kostas; Zdimal, Vladia; Schwarz, Jaroslav; Wagner, Zdenek; Ondracek, Jakub; Drossinos, Yannis; Glytsos, Thodoros; Vratolis, Sterios; Torseth, Kjetil; Moravec, Pavel; Hussein, Tareq; Smolik, Jiri |
Contributor organization: | Institute for Atmospheric and Earth System Research (INAR) |
Date: | 2017-01 |
Language: | eng |
Number of pages: | 16 |
Belongs to series: | Aerosol and Air Quality Research |
ISSN: | 1680-8584 |
DOI: | https://doi.org/10.4209/aaqr.2015.04.0267 |
URI: | http://hdl.handle.net/10138/232787 |
Abstract: | Indoor/outdoor aerosol size distribution was measured in four European cities (Oslo-Norway, Prague-Czech Republic, Milan-Italy and Athens-Greece) during 2002 in order to examine the differences in the characteristics of the indoor/outdoor modal structure and to evaluate the effect of indoor sources to the aerosol size distributions. All the measurement sites were naturally ventilated and were occupied during the campaigns by permanent residents or for certain time periods by the technical staff responsible for the instrumentation. Outdoor particle number (PN) concentrations presented the higher values in Milan and Athens (median values 1.4 x 10(4) # cm(-3) and 2.9 x 10(4) # cm(-3) respectively) as a result of elevated outdoor emissions and led to correspondingly higher indoor values compared to Oslo and Prague. In absence of indoor activities, the indoor concentrations followed the fluctuations of the outdoor concentrations in all the measurement sites. Indoor activities (cooking, smoking, etc.) resulted in elevated indoor PN concentrations (maximum values ranging between 1.7 x 10(5) # cm(-3) and 3.2 x 10(5) # cm(-3)) and to I/O ratios higher than one. The I/O ratios were size dependant and for periods without indoor activities, they presented the lowest values for particles <50 nm (0.51 +/- 0.15) and the ratios increased with fine particle size (0.79 +/- 0.12 for particles between 100-200 nm). The analysis of the modal structure showed that the indoor aerosol size distribution characteristics differ from the outdoors under the effect of indoor sources. The percentage of unimodal size distributions increased during indoor emissions, compared to periods without indoor sources, along with the number concentration of Aitken mode particles, indicating emissions in specific size ranges according to the type of the indoor source. |
Subject: |
Indoor/Outdoor aerosol
I/O ratio Modal structure Indoor sources AIRBORNE PARTICULATE MATTER INDOOR AIR-QUALITY ULTRAFINE PARTICLES SIZE DISTRIBUTIONS RESIDENTIAL HOUSES PERSONAL EXPOSURES AEROSOL-SIZE URBAN AREAS OUTDOOR HEALTH 114 Physical sciences 1172 Environmental sciences |
Peer reviewed: | Yes |
Rights: | unspecified |
Usage restriction: | openAccess |