Sisäilman epäpuhtauksien havainnointi ja vähentäminen vesiaerosolien avulla

Show full item record



Permalink

http://hdl.handle.net/10138/237083

Citation

Harmo , P , Selkäinaho , J , Salkinoja-Salonen , M , Siren , H M , Riekkola , M-L & Visala , A 2018 , ' Sisäilman epäpuhtauksien havainnointi ja vähentäminen vesiaerosolien avulla ' , SIY raportti , Vuosikerta. 36 , Sivut 413-418 .

Title: Sisäilman epäpuhtauksien havainnointi ja vähentäminen vesiaerosolien avulla
Alternative title: Observation and elimination of indoor air impurities using aqueous aerosols
Author: Harmo, Panu; Selkäinaho, Jorma; Salkinoja-Salonen, Mirja; Siren, Heli M.; Riekkola, Marja-Liisa; Visala, Arto
Contributor organization: Kemian osasto
Doctoral Programme in Chemistry and Molecular Sciences
Doctoral Programme in Materials Research and Nanosciences
Analyyttisen kemian laboratorio
Date: 2018-03-15
Language: fin
Number of pages: 6
Belongs to series: SIY raportti
ISSN: 1237-1866
URI: http://hdl.handle.net/10138/237083
Abstract: Mittasimme aineiden (hometoksiinit; rakennus- ja saneeraustuotteiden kemikaalit, siivousaineet) kulkeutumista päästölähteistä ilmaan tutkimuskammioissa. Tutkittavat aineet annosteltiin kammioiden pohjalla oleviin avoimiin astioihin. Kammioiden ilman kosteutta säädettiin lisäämällä pohjalle vettä ja ilmankostutin- ja kuivainlaitteilla. Lämpötilaa, kosteutta ja TVOC-pitoisuutta monitoroitiin jatkuvatoimisilla antureilla. Kammioilman vesihöyry ja vesiaerosolit tiivistettiin nestemäiseksi vedeksi kuivaimen säiliöön. Kun tiivistevesi analysoitiin, havaittiin, että mikrobitoksiinit (okratoksiini A, enniatiini B) ja siivous- ja saneeraustuotteiden sisältämät antimikrobiset (PHMG) aineet, neutraalit (polyglykoli-alkoksyylit) ja kationiset tensidit (DDDMAC) siirtyivät pinnoilta ilmaan ja sieltä ilmankuivaimen kondenssivesisäiliöön.We measured mobility of nonvolatile fungal toxins and chemical substances in products used in building construction or maintenance into indoor air. The measurement was conducted in enclosed chambers provided with sensors for continuous monitoring of air humidity, temperature, organic substance (TVOC). Airborn humidicity was cyclically up/down adjusted using humidifier / dehumidifier. Substances tested for emission, were placed in open dishes on chamber floor. Airborn humidity was condensed into liquid water, harvested in dehumidifer storage container, and analysed at the end of each experiment.We found that nonvolatile substances such as fungal toxins (ochratoxin A), non-ionic and cationic tensides (polyoxyethylene alkanol ethers, didecyldimethyl ammonium chloride) and antimicrobial biocidal substances (PHMG) , contained in cleaning and sanitation products in buildings, translocated were recovered in the the dehumidifer condensate, thus indicating airborn migration.
Description: Presented at Indoor Air Seminar (Helsinki, Finland) 15 March, 2018. ISBN 978-952-5236-46-0.
Subject: 218 Ympäristötekniikka
indoor air
cationic tenside
nonionic tenside
ochratoxin A
enniatin B
didecyl dimethyl ammonium chloridei ammonium kloridi
genapol X080
PHMG
polyhexamethylene guanidine chloride
sisäilma
biosidit
joniton tensidi
didekyyli-dimetyyli-ammonium kloridi
enniatiini B
okratoksiini A
genapol X080
isotridekyyli-polyglykoli eetteriri
hometoksiini
kereulidi
valinomysiini
PHMG
polyheksametyleeni guanidiini
hengityselinten sairaudet
siivousaineet
antimikrobiset kemikaalit
hengitysaltistuminen
Peer reviewed: Yes
Rights: unspecified
Usage restriction: openAccess
Self-archived version: publishedVersion


Files in this item

Total number of downloads: Loading...

Files Size Format View
HarmoEtaLSisem2018_s413_418.pdf 410.3Kb PDF View/Open
SISAILMASTO_seminaarijulkaisu2018.pdf 9.727Mb PDF View/Open

This item appears in the following Collection(s)

Show full item record