Development of the Finnish neurological function testing battery for dogs and its intra- and inter-rater reliability

Show full item record



Permalink

http://hdl.handle.net/10138/244332

Citation

Acta Veterinaria Scandinavica. 2018 Sep 17;60(1):56

Title: Development of the Finnish neurological function testing battery for dogs and its intra- and inter-rater reliability
Author: Boström, Anna F; Hyytiäinen, Heli K; Koho, Petteri; Cizinauskas, Sigitas; Hielm-Björkman, Anna K
Publisher: BioMed Central
Date: 2018-09-17
URI: http://hdl.handle.net/10138/244332
Abstract: Abstract Background The Finnish neurological function testing battery for dogs (FINFUN) was developed to meet the increasing demand for objective outcome measures in veterinary physiotherapy. The testing battery should provide consistent, reproducible results and have established face and content validity. Internal consistency and intra- and inter-rater reliability of the FINFUN were also investigated. Results The FINFUN comprised 11 tasks: lying, standing up from lying, sitting, standing up from sitting, standing, proprioceptive positioning, starting to walk, walking, trotting, walking turns and walking stairs. A score from 0 to 4, (0: unable to perform task, 4: performing task with normal motor function) was given for each task, the maximum score being 44. Twenty-six dogs were filmed when performing the FINFUN. Seven observers scored the performances from the video recordings. The FINFUN was considered to have appropriate face and content validity based on a pilot study, clinical experience and critical reflection of the development process. Its internal consistency was excellent, with no Cronbach’s alpha values below 0.922. The intra-rater reliability for total score of experienced observers was almost perfect: 0.999 (observer 1) and 0.994 (observer 2). The inter-rater reliability for both experienced and novice observers’ total scores was also almost perfect (0.919–0.993). Analysis of each individual task showed substantial intra-rater and inter-rater agreement for the tasks “lying” and “sitting”. Conclusions The FINFUN is an objective, valid and reliable tool with standardized scoring criteria for evaluation of motor function in dogs recovering from spinal cord injury.
Subject: Inter-rater reliability
Intra-rater reliability
Motor function
Neurology
Outcome measure
Physiotherapy
Testing battery
Validity
Rights: The Author(s)


Files in this item

Total number of downloads: Loading...

Files Size Format View
13028_2018_Article_408.pdf 792.1Kb PDF View/Open

This item appears in the following Collection(s)

Show full item record