Digitization and astrometric calibration of Carte du Ciel photographic plates with Gaia DR1

Show full item record



Permalink

http://hdl.handle.net/10138/246349

Citation

Lehtinen , K , Prusti , T , Bruijne , J D , Lammers , U , Manara , C F , Ness , J-U , Siddiqui , H , Markkanen , T , Poutanen , M & Muinonen , K 2018 , ' Digitization and astrometric calibration of Carte du Ciel photographic plates with Gaia DR1 ' , Astronomy & Astrophysics , vol. 616 , 185 . https://doi.org/10.1051/0004-6361/201832662

Title: Digitization and astrometric calibration of Carte du Ciel photographic plates with Gaia DR1
Author: Lehtinen, K.; Prusti, T.; Bruijne, J. de; Lammers, U.; Manara, C. F.; Ness, J.-U.; Siddiqui, H.; Markkanen, T.; Poutanen, M.; Muinonen, K.
Contributor organization: Department of Physics
Date: 2018-09-11
Language: eng
Number of pages: 18
Belongs to series: Astronomy & Astrophysics
ISSN: 0004-6361
DOI: https://doi.org/10.1051/0004-6361/201832662
URI: http://hdl.handle.net/10138/246349
Abstract: Context. Carte du Ciel was a global international project at the end of the nineteenth and beginning of the twentieth century to map the sky to about magnitude 14 on photographic plates. The full project was never observationally completed and a large fraction of the observations made remain unanalyzed. Aims. We want to study whether the astrometric and photometric accuracies obtained for the Carte du Ciel plates digitized with a commercial digital camera are high enough for scientific exploitation of the plates. Methods. We use a digital camera Canon EOS 5Ds, with a 100 mm macrolens for digitizing. We analyze six single-exposure plates and four triple-exposure plates from the Helsinki zone of Carte du Ciel (+39 degrees Results. The best astrometric accuracy is obtained with the UCAC5 reference stars. The astrometric accuracy for single-exposure plates is sigma(alpha cos(delta)) = 0.16 '' and sigma(delta) = 0.15 '', expressed as a Gaussian deviation of the astrometric residuals. For triple-exposure plates the astrometric accuracy is sigma(alpha cos(delta)) = 0.12 '' and sigma(delta) = 0.13 ''. The 1 - sigma uncertainty of photometric calibration is about 0.28 mag and 0.24 mag for single- and triple-exposure plates, respectively. We detect the photographic adjacency (Kostinsky) effect in the triple-exposure plates. Conclusions. We show that accuracies at least of the level of scanning machines can be achieved with a digital camera, without any corrections for possible distortions caused by our instrumental setup. This method can be used to rapidly and inexpensively digitize and calibrate old photographic plates enabling their scientific exploitation.
Subject: 114 Physical sciences
Peer reviewed: Yes
Rights: other
Usage restriction: openAccess
Self-archived version: publishedVersion


Files in this item

Total number of downloads: Loading...

Files Size Format View
aa32662_18.pdf 53.41Mb PDF View/Open

This item appears in the following Collection(s)

Show full item record