Iterative and discrete reconstruction in the evaluation of the rabbit model of osteoarthritis

Show full item record



Permalink

http://hdl.handle.net/10138/299702

Citation

Ketola , J H , Karhula , S S , Finnilä , M A J , Korhonen , R K , Herzog , W , Siltanen , S , Nieminen , M T & Saarakkala , S 2018 , ' Iterative and discrete reconstruction in the evaluation of the rabbit model of osteoarthritis ' , Scientific Reports , vol. 8 , no. 1 . https://doi.org/10.1038/s41598-018-30334-8

Title: Iterative and discrete reconstruction in the evaluation of the rabbit model of osteoarthritis
Author: Ketola, J.H.; Karhula, S.S.; Finnilä, M.A.J.; Korhonen, R.K.; Herzog, W.; Siltanen, S.; Nieminen, M.T.; Saarakkala, S.
Contributor: University of Helsinki, Department of Mathematics and Statistics
Date: 2018
Language: eng
Number of pages: 10
Belongs to series: Scientific Reports
ISSN: 2045-2322
URI: http://hdl.handle.net/10138/299702
Abstract: Micro-computed tomography (µCT) is a standard method for bone morphometric evaluation. However, the scan time can be long and the radiation dose during the scan may have adverse effects on test subjects, therefore both of them should be minimized. This could be achieved by applying iterative reconstruction (IR) on sparse projection data, as IR is capable of producing reconstructions of sufficient image quality with less projection data than the traditional algorithm requires. In this work, the performance of three IR algorithms was assessed for quantitative bone imaging from low-resolution data in the evaluation of the rabbit model of osteoarthritis. Subchondral bone images were reconstructed with a conjugate gradient least squares algorithm, a total variation regularization scheme, and a discrete algebraic reconstruction technique to obtain quantitative bone morphometry, and the results obtained in this manner were compared with those obtained from the reference reconstruction. Our approaches were sufficient to identify changes in bone structure in early osteoarthritis, and these changes were preserved even when minimal data were provided for the reconstruction. Thus, our results suggest that IR algorithms give reliable performance with sparse projection data, thereby recommending them for use in µCT studies where time and radiation exposure are preferably minimized. © 2018, The Author(s).
Subject: 217 Medical engineering
111 Mathematics
Rights:


Files in this item

Total number of downloads: Loading...

Files Size Format View
s41598_018_30334_8.pdf 1.660Mb PDF View/Open

This item appears in the following Collection(s)

Show full item record