Lindström , M , Tohmola , N , Renkonen , R , Hämäläinen , E , Schalin-Jäntti , C & Itkonen , O 2018 , ' Comparison of serum serotonin and serum 5-HIAA LC-MS/MS assays in the diagnosis of serotonin producing neuroendocrine neoplasms : A pilot study ' , Clinica Chimica Acta , vol. 482 , pp. 78-83 . https://doi.org/10.1016/j.cca.2018.03.030
Title: | Comparison of serum serotonin and serum 5-HIAA LC-MS/MS assays in the diagnosis of serotonin producing neuroendocrine neoplasms : A pilot study |
Author: | Lindström, Mikael; Tohmola, Niina; Renkonen, Risto; Hämäläinen, Esa; Schalin-Jäntti, Camilla; Itkonen, Outi |
Contributor organization: | HUSLAB Clinicum Medicum University of Helsinki Infection Biology Research Program Risto Renkonen / Principal Investigator Transplantation Laboratory Department of Diagnostics and Therapeutics Department of Medicine Endokrinologian yksikkö HUS Abdominal Center |
Date: | 2018-07 |
Language: | eng |
Number of pages: | 6 |
Belongs to series: | Clinica Chimica Acta |
ISSN: | 0009-8981 |
DOI: | https://doi.org/10.1016/j.cca.2018.03.030 |
URI: | http://hdl.handle.net/10138/300392 |
Abstract: | Background: Serotonin (5-hydroxytyramine) is a mediator of gastrointestinal smooth muscle contraction, and is secreted by neuroendocrine neoplasms (NENs). We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum serotonin to be used in NEN diagnostics and follow-up. Methods: We used serum samples from healthy volunteers (n = 31) and patients suspected or monitored for NEN (n = 98). Serotonin-D-4 internal standard was added to samples before solid phase extraction (SPE) and quantification by LC-MS/MS. The effects of sample handling and preparation on serotonin stability were studied. Finally, we established a provisional reference range for serum serotonin and compared our assay with serum 5hydroxyindoleacetic acid (5-HIAA) for detection of NENs. Results: Our assay is sensitive and has a wide linear range (10-10,000 nmo1/1). Serum serotonin is stable for 7 days at room temperature and for 3 months at -20 degrees C. Sampling temperature is not critical. Normal range for serum serotonin was 270-1490 nmo1/1. We found that serum serotonin and 5-HIAA performed equally well as diagnostic tests for NENs. Conclusions: Our LC-MS/MS assay for serum serotonin is well suited for clinical research and patient diagnostics. Our results confirm that it can complement 5-HIAA in diagnosis of NENs. |
Subject: |
Serotonin
5-HIAA NEN Neuroendocrine neoplasm LC-MS/MS TANDEM MASS-SPECTROMETRY POOR PLASMA SEROTONIN PLATELET-RICH PLASMA LIQUID-CHROMATOGRAPHY CARCINOID-TUMORS URINE METABOLITES ACID 3111 Biomedicine |
Peer reviewed: | Yes |
Rights: | cc_by_nc_nd |
Usage restriction: | openAccess |
Self-archived version: | acceptedVersion |
Total number of downloads: Loading...
Files | Size | Format | View |
---|---|---|---|
1_s2.0_S0009898118301463_main.pdf | 430.1Kb |
View/ |
|
1_s2.0_S0009898118301463_main.pdf | 476.9Kb |
View/ |