Calibration of the photon spectrometer PHOS of the ALICE experiment

Näytä kaikki kuvailutiedot



Pysyväisosoite

http://hdl.handle.net/10138/303461

Lähdeviite

The ALICE Collaboration , Acharya , S , Brucken , E J , Chang , B , Hilden , T E , Kim , D J , Litichevskyi , V , Mieskolainen , M M , Orava , R , Parkkila , J E , Rak , J , Räsänen , S S , Saarinen , S , Slupecki , M , Snellman , T W , Trzaska , W H , Vargyas , M & Viinikainen , J 2019 , ' Calibration of the photon spectrometer PHOS of the ALICE experiment ' , Journal of Instrumentation , vol. 14 , P05025 . https://doi.org/10.1088/1748-0221/14/05/P05025

Julkaisun nimi: Calibration of the photon spectrometer PHOS of the ALICE experiment
Tekijä: The ALICE collaboration; Acharya, S.; Brucken, E. J.; Chang, B.; Hilden, T. E.; Kim, D. J.; Litichevskyi, V.; Mieskolainen, M. M.; Orava, R.; Parkkila, J. E.; Rak, J.; Räsänen, S. S.; Saarinen, S.; Slupecki, M.; Snellman, T. W.; Trzaska, W. H.; Vargyas, M.; Viinikainen, J.
Muu tekijä: University of Helsinki, Helsinki Institute of Physics
University of Helsinki, University of Jyväskylä
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, University of Jyväskylä
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, University of Jyväskylä
University of Helsinki, University of Jyväskylä
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, University of Jyväskylä
University of Helsinki, University of Jyväskylä
University of Helsinki, University of Jyväskylä
Päiväys: 2019-05
Kieli: eng
Sivumäärä: 30
Kuuluu julkaisusarjaan: Journal of Instrumentation
ISSN: 1748-0221
URI: http://hdl.handle.net/10138/303461
Tiivistelmä: The procedure for the energy calibration of the high granularity electromagnetic calorimeter PHOS of the ALICE experiment is presented. The methods used to perform the relative gain calibration, to evaluate the geometrical alignment and the corresponding correction of the absolute energy scale, to obtain the nonlinearity correction coefficients and finally, to calculate the time-dependent calibration corrections, are discussed and illustrated by the PHOS performance in proton-proton (pp) collisions at root s = 13 TeV. After applying all corrections, the achieved mass resolutions for pi(0) and eta mesons for p(T) > 1.7 GeV/c are sigma(pi 0)(m) = 4.56 +/- 0.03 MeV/c(2) and sigma(eta)(m) = 15.3 +/- 1.0 MeV/c(2), respectively.
Avainsanat: Calorimeters
Detector alignment and calibration methods (lasers, sources, particlebeams)