Dry contact electrodes performance in canine ECG

Show full item record



Permalink

http://hdl.handle.net/10138/310403

Citation

Virtanen , J , Leivo , J , Vehkaoja , A , Somppi , S , Tornqvist , H , Fiedler , P , Vaataja , H & Surakka , V 2018 , Dry contact electrodes performance in canine ECG . in ACI'18: Proceedings of the Fifth International Conference on Animal-Computer Interaction . ACM , New York , International Conference on Animal-Computer Interaction , Atlanta , United States , 04/12/2018 . https://doi.org/10.1145/3295598.3295609

Title: Dry contact electrodes performance in canine ECG
Author: Virtanen, Juhani; Leivo, Joni; Vehkaoja, Antti; Somppi, Sanni; Tornqvist, Heini; Fiedler, Patrique; Vaataja, Heli; Surakka, Veikko
Contributor: University of Helsinki, Equine and Small Animal Medicine
University of Helsinki, Equine and Small Animal Medicine
Publisher: ACM
Date: 2018
Language: eng
Number of pages: 5
Belongs to series: ACI'18: Proceedings of the Fifth International Conference on Animal-Computer Interaction
ISBN: 978-1-4503-6219-1
URI: http://hdl.handle.net/10138/310403
Abstract: Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
Subject: Canine
Electrocardiogram
Dry Electrode
HEART-RATE-VARIABILITY
113 Computer and information sciences
1181 Ecology, evolutionary biology