Dry contact electrodes performance in canine ECG

Visa fullständig post



Permalänk

http://hdl.handle.net/10138/310403

Citation

Virtanen , J , Leivo , J , Vehkaoja , A , Somppi , S , Tornqvist , H , Fiedler , P , Vaataja , H & Surakka , V 2018 , Dry contact electrodes performance in canine ECG . in ACI'18: Proceedings of the Fifth International Conference on Animal-Computer Interaction . ACM , New York , International Conference on Animal-Computer Interaction , Atlanta , Georgia , United States , 04/12/2018 . https://doi.org/10.1145/3295598.3295609

Titel: Dry contact electrodes performance in canine ECG
Författare: Virtanen, Juhani; Leivo, Joni; Vehkaoja, Antti; Somppi, Sanni; Tornqvist, Heini; Fiedler, Patrique; Vaataja, Heli; Surakka, Veikko
Upphovmannens organisation: Equine and Small Animal Medicine
Utgivare: ACM
Datum: 2018
Språk: eng
Sidantal: 5
Tillhör serie: ACI'18: Proceedings of the Fifth International Conference on Animal-Computer Interaction
ISBN: 978-1-4503-6219-1
DOI: https://doi.org/10.1145/3295598.3295609
Permanenta länken (URI): http://hdl.handle.net/10138/310403
Abstrakt: Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
Subject: Canine
Electrocardiogram
Dry Electrode
HEART-RATE-VARIABILITY
113 Computer and information sciences
1181 Ecology, evolutionary biology
Referentgranskad: Ja
Licens: unspecified
Användningsbegränsning: openAccess
Parallelpublicerad version: publishedVersion


Filer under denna titel

Totalt antal nerladdningar: Laddar...

Filer Storlek Format Granska
3295598.3295609.pdf 457.9Kb PDF Granska/Öppna

Detta dokument registreras i samling: