The DAQ and control system for the CMS Phase-1 pixel detector upgrade

Show full item record



Permalink

http://hdl.handle.net/10138/311177

Citation

The CMS Collaboration , Adam , W , Eerola , P , Heikkilä , J , Brucken , E , Lampen , T , Luukka , P , Martikainen , L , Tuominen , E & Tuuva , T 2019 , ' The DAQ and control system for the CMS Phase-1 pixel detector upgrade ' , Journal of Instrumentation , vol. 14 , 10017 . https://doi.org/10.1088/1748-0221/14/10/P10017

Title: The DAQ and control system for the CMS Phase-1 pixel detector upgrade
Author: The CMS collaboration; Adam, W.; Eerola, P.; Heikkilä, J.; Brucken, E.; Lampen, T.; Luukka, P.; Martikainen, L.; Tuominen, E.; Tuuva, T.
Contributor: University of Helsinki, Department of Physics
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, Helsinki Institute of Physics
University of Helsinki, Eija Tuominen / Principal Investigator
Date: 2019-10
Language: eng
Number of pages: 35
Belongs to series: Journal of Instrumentation
ISSN: 1748-0221
URI: http://hdl.handle.net/10138/311177
Abstract: In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included.
Subject: Data acquisition concepts
Detector control systems (detector and experiment monitoring and slow-control systems, architecture, hardware, algorithms, databases)
Modular electronics
Optical detector readout concepts
READOUT
213 Electronic, automation and communications engineering, electronics
Rights:


Files in this item

Total number of downloads: Loading...

Files Size Format View
Adam_2019_J._Inst._14_P10017.pdf 16.04Mb PDF View/Open

This item appears in the following Collection(s)

Show full item record