Quality Control Analysis in Real-time (QC-ART) : A Tool for Real-time Quality Control Assessment of Mass Spectrometry-based Proteomics Data

Show full item record



Permalink

http://hdl.handle.net/10138/313757

Citation

TEDDY STUDY GRP , Stanfill , B A , Nakayasu , E S , Bramer , L M & Knip , M 2018 , ' Quality Control Analysis in Real-time (QC-ART) : A Tool for Real-time Quality Control Assessment of Mass Spectrometry-based Proteomics Data ' , Molecular & Cellular Proteomics , vol. 17 , no. 9 , pp. 1824-1836 . https://doi.org/10.1074/mcp.RA118.000648

Title: Quality Control Analysis in Real-time (QC-ART) : A Tool for Real-time Quality Control Assessment of Mass Spectrometry-based Proteomics Data
Author: TEDDY STUDY GRP; Stanfill, Bryan A.; Nakayasu, Ernesto S.; Bramer, Lisa M.; Knip, Mikael
Contributor: University of Helsinki, Children's Hospital
Date: 2018-09
Language: eng
Number of pages: 13
Belongs to series: Molecular & Cellular Proteomics
ISSN: 1535-9476
URI: http://hdl.handle.net/10138/313757
Abstract: Liquid chromatography-mass spectrometry (LC-MS)-based proteomics studies of large sample cohorts can easily require from months to years to complete. Acquiring consistent, high-quality data in such large-scale studies is challenging because of normal variations in instrumentation performance over time, as well as artifacts introduced by the samples themselves, such as those because of collection, storage and processing. Existing quality control methods for proteomics data primarily focus on post-hoc analysis to remove low-quality data that would degrade downstream statistics; they are not designed to evaluate the data in near real-time, which would allow for interventions as soon as deviations in data quality are detected. In addition to flagging analyses that demonstrate outlier behavior, evaluating how the data structure changes over time can aide in understanding typical instrument performance or identify issues such as a degradation in data quality because of the need for instrument cleaning and/or re-calibration. To address this gap for proteomics, we developed Quality Control Analysis in Real-Time (QC-ART), a tool for evaluating data as they are acquired to dynamically flag potential issues with instrument performance or sample quality. QC-ART has similar accuracy as standard post-hoc analysis methods with the additional benefit of real-time analysis. We demonstrate the utility and performance of QC-ART in identifying deviations in data quality because of both instrument and sample issues in near real-time for LC-MS-based plasma proteomics analyses of a sample subset of The Environmental Determinants of Diabetes in the Young cohort. We also present a case where QC-ART facilitated the identification of oxidative modifications, which are often underappreciated in proteomic experiments.
Subject: LC-MS/MS
PERFORMANCE METRICS
BIOLOGICAL CONSEQUENCES
SOFTWARE
IDENTIFICATION
QUANTITATION
3111 Biomedicine
1182 Biochemistry, cell and molecular biology
Rights:


Files in this item

Total number of downloads: Loading...

Files Size Format View
1824.full.pdf 2.054Mb PDF View/Open

This item appears in the following Collection(s)

Show full item record