TY - T1 - Pelvic organ prolapse repair using the Uphold (TM) Vaginal Support System : a 1-year multicenter study SN - / UR - http://hdl.handle.net/10138/225169 T3 - A1 - Altman, Daniel; Mikkola, Tomi S.; Bek, Karl Moller; Rahkola-Soisalo, Paivi; Gunnarsson, Jonas; Engh, Marie Ellstrom; Falconer, Christian; Nordic TVM Grp A2 - PB - Y1 - 2016 LA - eng AB - The objective was to assess safety and clinical outcomes in women operated on using the Uphold (TM) Lite Vaginal Support System. We carried out a 1-year, multicenter, prospective, single cohort study of 207 women with symptomatic Pelvic Organ Prolapse Quantification (POP-Q) stage aeyen2 apical pelvic organ prolapse, with or without concomitant anterior vaginal wall prolapse. Safety data were collected using a standardized questionnaire. Anatomical outcome was assessed by the POP-Q and subjective... VO - IS - SP - OP - KW - Complications; Mesh; Pelvic organ prolapse; RANDOMIZED CONTROLLED-TRIAL; TRANSVAGINAL MESH; ABDOMINAL SACROCOLPOPEXY; ANTERIOR; SURGERY; OUTCOMES; 3123 Gynaecology and paediatrics; 3126 Surgery, anesthesiology, intensive care, radiology N1 - PP - ER -