"Dirty coagulation" technique as an alternative to microclips for control of bleeding from deep feeders during brain arteriovenous malformation surgery

Show full item record



Permalink

http://hdl.handle.net/10138/234742

Citation

Kozyrev , D , Thiarawat , P , Rezai Jahromi , B , Intarakhao , P , Choque-Velasquez , J , Hijaz , F , Teo , M K & Hernesniemi , J 2017 , ' "Dirty coagulation" technique as an alternative to microclips for control of bleeding from deep feeders during brain arteriovenous malformation surgery ' , Acta Neurochirurgica , vol. 159 , no. 5 , pp. 855-859 . https://doi.org/10.1007/s00701-017-3138-8

Title: "Dirty coagulation" technique as an alternative to microclips for control of bleeding from deep feeders during brain arteriovenous malformation surgery
Author: Kozyrev, Danil; Thiarawat, Peeraphong; Rezai Jahromi, Behnam; Intarakhao, Patcharin; Choque-Velasquez, Joham; Hijaz, Ferzat; Teo, Mario K.; Hernesniemi, Juha
Contributor organization: Clinicum
Neurokirurgian yksikkö
Department of Neurosciences
HUS Neurocenter
Date: 2017-05
Language: eng
Number of pages: 5
Belongs to series: Acta Neurochirurgica
ISSN: 0001-6268
DOI: https://doi.org/10.1007/s00701-017-3138-8
URI: http://hdl.handle.net/10138/234742
Abstract: Meticulous haemostasis is one of the most important factors during microneurosurgical resection of brain arteriovenous malformation (AVM). Controlling major arterial feeders and draining veins with clips and bipolar coagulation are well-established techniques, while managing with bleeding from deep tiny vessels still proves to be challenging. This technical note describes a technique used by the senior author in AVM surgery for last 20 years in dealing with the issue highlighted. "Dirty coagulation" is a technique of bipolar coagulation of small feeders carried out together with a thin layer of brain tissue that surrounds these fragile vessels. The senior author uses this technique for achieving permanent haemostasis predominantly in large and/or deep-seated AVMs. To illustrate the efficacy of this technique, we retrospectively reviewed the outcome of Spetzler-Martin (SM) grade III-V AVMs resected by the senior author over the last 5 years (2010-2015). Thirty-five cases of AVM surgeries (14 SM grade III, 15 SM grade IV and 6 SM grade V) in this 5-year period were analysed. No postoperative intracranial haemorrhage was encountered as a result of bleeding from the deep feeders. Postoperative angiograms showed complete resection of all AVMs, except in two cases (SM grade V and grade III). "Dirty coagulation" provides an effective way to secure haemostasis from deep tiny feeders. This cost-effective method could be successfully used for achieving permanent haemostasis and thereby decreasing postoperative haemorrhage in AVM surgery.
Subject: Arteriovenous malformation
Bipolar coagulation
Microneurosurgery
Neurosurgical trick
MANAGEMENT
RESECTION
OUTCOMES
3124 Neurology and psychiatry
3126 Surgery, anesthesiology, intensive care, radiology
Peer reviewed: Yes
Rights: unspecified
Usage restriction: openAccess
Self-archived version: publishedVersion


Files in this item

Total number of downloads: Loading...

Files Size Format View
Dirty_coagulation_technique.pdf 599.4Kb PDF View/Open

This item appears in the following Collection(s)

Show full item record